I have just returned from vacation on a Western Caribbean cruise touching ports in Grand Cayman, Cartagena, Panama, Costa Rica, Honduras and Mexico in all those ports I confirmed that our Caribbean is wonderful and that the combination of high temperature and humidity are determining factors to control to maintain not only the desired comfort, but also minimize energy consumption when the air conditioning system to use is of direct expansion. Which has motivated me to share my experience with you in this Opinion column.

Temperature and humidity control is also important for maintaining indoor air quality. Two-position control systems (on and off) have been used for many years, however, the marked fluctuations in these variables create situations where when the temperature is satisfied, the humidity creates discomfort and when the humidity could be satisfied, the conditioned area could be overcooled. This not only creates discomfort but also a waste of energy.

Even when the hot gas bypass is used and the system is operating at partial loads, the two-position compressor shuts down due to low suction pressure and also because the system does not generate enough hot gas to operate continuously at such partial loads.

The technology of the control of direct expansion systems has evolved in recent years and modulating compressors are currently available to meet the needs of temperature and humidity control in the most efficient way possible since they proportionally adjust to the load of the conditioned area.

- Publicidad -

The modulating compressor, to satisfy both the load by sensitive and latent heat, will not cycle between on and off as do the compressors that their control is of two positions, which cycle constantly to satisfy the load. The modulating compressor will stay on longer, thus maintaining the best possible control of temperature and humidity and minimizing the electrical consumption that is created each time it starts.

Air conditioning systems operate most of the time at part loads and really the problem is created under that condition, especially when there is a great absence of sensitive heat. When comparing a system with a modulating compressor and a two-position compressor using hot gas, the modulant is approximately 35% more efficient.



AAON is the manufacturer that has spent the most time researching and developing direct expansion units using modulating compressors, especially in 100% outdoor air applications. The operation of the modulating compressor is very simple, the motor operates continuously, however, the pumping of refrigerant from the compressor consists of two stages. In the stage called "loaded", the compressor operates as a normal compressor type "Scroll" and supplies 100% of the refrigerant mass, the stage called "discharged" supplies 0% refrigerant.

The time of each stage is controlled through a solenoid valve that allows the supply of refrigerant. This valve allows the "scrolls" inside the compressor to separate and cannot compress the refrigerant, when the solenoid is reactivated the "scrolls" are joined again and discharge the compressed refrigerant. The time the solenoid is at each stage within a cycle is what determines the percentage of capacity.

For example, in cycles of 20 seconds, if the compressor is charged for 4 seconds and unloaded for 16 seconds, then the capacity is 20%. However, if it is charged for 10 seconds and unloaded for 10 seconds, then the capacity is 50%.

A simple and practical example of the application of these units has been a movie theater in Panama where the humidity is extremely high and in the first theaters they built they were presented with problems of humidity control and / or overcooling. They originally used 15-ton direct expansion units with two compressors of 7.5 tons each. Especially when the rooms were with few people, less load than the 7.5 tons of one of the compressors, when the temperature was satisfied and the compressor was turned off, the humidity increased considerably creating an unpleasant environment.

In the newly opened rooms, weatherproof roof units with 2" insulation and two compressors of 7.5 tons each were installed. One of the compressors is modulating to meet partial loads and the other two-position compressor. As the load increases, the modulating compressor increases its capacity, once it reaches 100% of its capacity, the second compressor goes into operation and the modulant is completely discharged. Once the capacity continues to increase, the modulating compressor begins to increase its capacity proportionally to the growth of the load.

These units with modulating compressors, not only satisfy the need to maintain comfort at any partial load, but also their efficiency is higher when compared to the original two-position units (on and off) non-modulating.

- Publicidad -

These direct expansion units with modulating compressors offer a practical and economical solution since they obtain the desired comfort and the energy savings justify the investment in a very short time.

No comments

• If you're already registered, please log in first. Your email will not be published.

Leave your comment

In reply to Some User
RefriAméricas 2026 will focus its Academic Congress on efficiency, decarbonization and technological transformation in HVAC/R

RefriAméricas 2026 will focus its Academic Congress on efficiency, decarbonization and technological transformation in HVAC/R

United States. The RefriAméricas 2026 Academic Congress will have as its thematic axis the "Efficiency, decarbonization and technological transformation in HVAC/R", a proposal that seeks to respond...

Johnson Controls highlights the impact of energy efficiency in critical industries in its 2026 Sustainability Report

Johnson Controls highlights the impact of energy efficiency in critical industries in its 2026 Sustainability Report

International. The company presented its 2026 Sustainability Report, in which it outlines advances in decarbonization, energy efficiency, and performance in critical environments such as hospitals,...

Jeff Littleton Announces Retirement as Executive Vice President

Jeff Littleton Announces Retirement as Executive Vice President

United States. The organization announced the retirement of Jeff Littleton as executive vice president of the organization, a position he will leave at the beginning of 2027, after more than two...

AHR Expo Mexico 2025 was recognized as the Best Event of the Year at EVENTUS 29

AHR Expo Mexico 2025 was recognized as the Best Event of the Year at EVENTUS 29

Mexico. During the EVENTUS 29 gala, held as part of Cintermex's 35th anniversary, the 2025 edition of AHR Expo Mexico 2025 received recognition as the "Best Event of the Year", a distinction awarded...

Refrigerated transport opens up opportunities to reduce water consumption in the cold chain

Refrigerated transport opens up opportunities to reduce water consumption in the cold chain

Mexico. Cold chain logistics faces new challenges in the face of the growing need to make more efficient use of natural resources. Beyond ensuring operational efficiency, refrigerated cargo...

Technical Training Drives Strengthening HVAC Talent

Technical Training Drives Strengthening HVAC Talent

Costa Rica. Samsung and the Costa Rican company Total Air held the series of talks "Technical Training in Samsung – Total Air DVM S2 Systems", an initiative aimed at strengthening technical...

ASHRAE Highlights Industry Priorities in Technical Program for its 2026 Annual Conference

ASHRAE Highlights Industry Priorities in Technical Program for its 2026 Annual Conference

United States. ASHRAE unveiled the technical program for its 2026 Annual Conference, which will be held June 27-July 1 in Austin and will bring together professionals from the HVAC&R industry to...

The KNX standard is consolidated in Chile: experts demystify building automation with a view to a sustainable future

The KNX standard is consolidated in Chile: experts demystify building automation with a view to a sustainable future

Santiago, Chile. The smart construction sector in Chile took a relevant step with the holding of the Building Automation Days by KNX LATAM Virtual, Chile 2026, an informative and educational space...

The Invisible Power of Cold: Thermal Efficiency for Data Centers in the Age of Artificial Intelligence

The Invisible Power of Cold: Thermal Efficiency for Data Centers in the Age of Artificial Intelligence

International. Behind the digital cloud and artificial intelligence there is a complex, dense and constantly operating physical infrastructure. In this environment, the cold becomes an invisible...

Expo Frío Calor Chile 2026 successfully closes and consolidates its position in the HVAC/R industry

Expo Frío Calor Chile 2026 successfully closes and consolidates its position in the HVAC/R industry

Chile. With an agenda focused on innovation, sustainability and professional development, Expo Frío Calor Chile 2026 ended after three intense days held at Centro Parque, consolidating itself as the...

Free Subscription
Remember Me
SUBSCRIBE TO OUR NEWSLETTER
DO YOU NEED A SERVICE OR PRODUCT QUOTE?
LASTEST INTERVIEWS
SITE SPONSORS










LASTEST NEWSLETTER
Ultimo Info-Boletin