New composition of a next-generation refrigerant with low GWP developed

refrigerantes

International. A Japanese refrigerant specialist announced the development of the new HFO-1123 blend, a low-GWP refrigerant that is expected to be the next-generation standard for air conditioners; a work carried out in cooperation with the University of Tokyo.

Manufactured by the company AGC, this would be the first refrigerant in the world with GWP less than 10 for air conditioners, which has entered the final stage.

The Kigali Amendment to the Montreal Protocol has mandated a significant reduction in the production and consumption of HFCs. In particular, refrigerants used in air conditioners for homes and stores account for the largest share of the global market, making the development of refrigerants with low GWP an urgent problem.

To solve this problem, AGC's hydrofluoroolefin (HFO) AMOLEA™1123 is expected to be a candidate to reduce HFCs. AMOLEA™ 1123 is an HFO developed by AGC in 2014 as part of the project funded by the New Energy and Industrial Technology Development Organization (NEDO) of Japan. It is a refrigerant that combines extraordinarily high environmental performance with a GWP of less than 1, maintaining the same performance as the HFC R410A currently used (GWP 2090 /2090 times the greenhouse effect compared to CO2).

- Publicidad -

The University of Tokyo and AGC have managed to develop a safe composition that suppresses the rapid increase in pressure due to the decomposition of AMOLEA™ 1123 to a certain level by the addition of propane, according to the findings of the NEDO project "Development of Technology and Evaluation Techniques for next-generation refrigerants with a low GWP value" commissioned by the University of Tokyo.

The new composition of AMOLEA™ 1123 (GWP 0.3 or greenhouse effect of 1/3 of CO2) consists of a certain percentage of propane (R290: GWP 3 or greenhouse effect of 3 times CO2), which is a versatile refrigerant with low GWP. With this achievement, the development of a refrigerant with a GWP of 10 or less has made significant progress and entered the final stage.

Based on the results of this development, AGC will sequentially launch new refrigerants with ultra-low GWP and high safety, for use in a variety of equipment, including residential and commercial air conditioners. In addition, as a next-generation refrigerant for electric vehicles, the mixed refrigerant AMOLEA™ 1123 (AMOLEA™ 10X) with a GWP of 10 or less, to be applied for ASHRAE in June 2022, is under consideration for certification in 2025 by SAE.

Duván Chaverra Agudelo
Author: Duván Chaverra Agudelo
Jefe Editorial en Latin Press, Inc,.
Comunicador Social y Periodista con experiencia de más de 16 años en medios de comunicación. Apasionado por la tecnología y por esta industria. dchaverra@latinpressinc.com

No thoughts on “New composition of a next-generation refrigerant with low GWP developed”

• If you're already registered, please log in first. Your email will not be published.

Leave your comment

In reply to Some User
Free Subscription
SUBSCRIBE TO OUR NEWSLETTER
DO YOU NEED A SERVICE OR PRODUCT QUOTE?
LASTEST INTERVIEWS

Bienvenida a Air Conditioning for Hospitals Summit

Sesión 5: Desinfección en ambientes críticos bajo recomendaciones de ASHRAE

Esta charla estará enfocada en las recomendaciones de ASHARAE para la desinfección de ambientes críticos como lo son quirófanos o salas de hospitales, garantizando una ventilación adecuada para reducir el riesgo de infección. Nos enfocaremos en los productos que Carrier ha lanzado al mercado para cubrir esta necesidad inmediata. Ing.William Sanchez - Grupo Clima https://www.acrlatinoamerica.com/20...

Sesión 4: Minimizando las Infecciones Asociadas a la Atención de la Salud (IAAS)

Como se pueden minimizar las Infecciones Asociadas a la Atención de la Salud (IAAS) al proveer el flujo de aire y la presurización adecuada en los ambientes críticos. Roberto Rouanet, Business Developer Building Products - Siemens Colombia https://www.acrlatinoamerica.com/20...

Sesión 3: Hospitales: Salas de Presión Positiva y Negativa

Los centros hospitalarios tienen requerimientos de salas o zonas de presión positiva y negativa con el objetivo de proteger a sus pacientes, trabajadores y usuarios de las áreas de infecciosos (salas de presión negativa) o inmunodeprimidos (salas de presión positiva). Estos espacios aislados por diferencias de presión se consiguen a través de los sistemas de control de los equipos de climatización de las instalaciones. Estas salas de presión Negativa o Positiva son una parte imprescindible en centros médicos y de investigación, ya que ayudan a mantener las condiciones sanitarias necesarias para un ambiente limpio. Jose Jesús Arboledas Herranz, Responsable de proyectos especiales - KEYTER https://www.acrlatinoamerica.com/20...

Sesión 1: Panel - Buenas prácticas, normativas y errores en climatización para hospitales

Buenas prácticas, normativas y errores más comunes en los proyectos de climatización para hospitales Analizar cuáles son los temas en los que los ingenieros y técnicos deben capacitarse profundamente para desarrollar proyectos en esta clase de verticales que demandan instalaciones funcionales al 100% Roberto D'Anetra, Gerente - Climatiza Rómulo Laureano, Commercial Sales Manager - RGF-BIOCONTROLS Jose Jesús Arboledas Herranz, Responsable de proyectos especiales - KEYTER Roberto Rouanet, Business Developer Building Products - Siemens Colombia https://www.acrlatinoamerica.com/20...
Load more...
SITE SPONSORS










LASTEST NEWSLETTER
Ultimo Info-Boletin